WebMar 1, 2024 · Put the particular switch or all the switches in stack in standalone mode, this can be done by issuing following command: Switch (config)#stack-power switch Switch (config-switch-stackpower)#standalone Once this is done, wait for 60-90 seconds and see if the error message goes away. WebOct 28, 2024 · The Stack Port Status value for Port 2 on Switch 1 is Absent, and the value for Port 1 on Switch 2 is Down. The Cable Length value is No cable. Diagnosing the problem: Verify the cable connection for Port 2 on Switch 1. Port 2 on Switch 1 has a port or cable problem if The In Loopback value is Yes. or
Catalyst 2960-X Switch Stack Manager Command Reference, Cisco …
WebOct 13, 2010 · with show version you see the Uptime all 3750 in the cluster first comes Switch 01: hostname: uptime is 6 days, 6 hours, 44 minutes Switch 02 --------- Switch Uptime : 6 days, 7 hours, 5 minutes Regards JP View solution in original post 0 Helpful Share Reply 5 Replies Jean-Pierre Burlet Beginner Options 10-13-2010 01:53 AM Hi … WebApr 3, 2024 · The output displays detailed status of the currently running stack mode. ... Device# show switch stack-mode Switch Role Mac Address Version Mode Configured State ----- 1 Member 3c5e.c357.c880 1+1' Active' Ready *2 Active 547c.69de.cd00 ... Use Cisco Feature Navigator to find information about platform and software image support. ... fochea blender assembly
Stacking and High Availability Configuration Guide, Cisco IOS XE …
WebDec 17, 2014 · Power stack on my switch show ports in status Shut, there is a way to do a no shut in a way to enable those ports ? Power stack name: Powerstack-1 Stack mode: Redundant Stack topology: Standalone Switch 1: Power budget: 192 Power allocated: 192 Low port priority value: 22 High port priority value: 13 Switch priority value: 4 Port 1 … WebApr 3, 2024 · Cisco Catalyst 9300L Series Switches stack with only Cisco Catalyst 9300L Series Switches as stack members. C9300-24UB, C9300-24UXB, and C9300-48UB switches can only be stacked with each other. ... This is the port status: # show switch stack-ports summary # Sw#/Port# Port Neighbor Cable Link Link Sync #Changes In … WebStacking port. Disabled. if we do a switch reboot (eg reboot switch 1 or 2) , we are seeing a 30 second outage before the firewall interface on VLAN123 is available again , what we are expecting is almost a instant / 1-2 second outage. We made a change on the firewall side , changing it from Passive SLOW LACP to Passive FAST LACP. fochea 3 in 1 blender